Solplanet H-T2 and H-T3 Hybrid Inverters for 3×230 V: Synergrid Overview

Solplanet ASW10kH-T3

For Belgian installers

Three-phase hybrid Solplanet inverters for a 3×230 V grid

The ASW H-T2 and H-T3 series are on the Belgian Synergrid C10/26 list with specific 3×230 V delta powers.

Solplanet ASW H-T2 and H-T3 three-phase hybrid inverter for 3x230 V

A three-phase 3x230 V network without neutral conductor requires an inverter that is expressly included in the Belgian homologation list. For installers, Solar-West has brought together the relevant Solplanet ASW H-T2 and H-T3 models below, including the powers stated by Synergrid for connection in delta 3×230 V.

Important: the type designation of the inverter remains 5, 6, 8, 10 or 12 kW, but a lower maximum apparent power applies to a 3×230 V delta grid. Therefore, always use the Belgian grid setting, the correct firmware and the prescribed meter configuration.

Which Solplanet hybrid inverters are suitable for 3×230 V?

The current Synergrid C10/26 list lists the following Solplanet models as “connected in Delta 3*230 grid”, with firmware V1.0 and the Eastron SDM630-Modbus.

SeriesModelMax. power at 3×230 VView product
H‑T2ASW05kH‑T22.9kVAView product
H‑T2ASW06kH‑T23.5kVAView product
H‑T2ASW08kH‑T24.6kVAView product
H‑T2ASW10kH‑T25.8kVAView product
H‑T2ASW12kH‑T26.9kVAView product
H‑T3ASW08kH‑T34.6kVAView product
H‑T3ASW10kH‑T35.8kVAView product
H‑T3ASW12kH‑T36.9kVAView product

H-T2 or H-T3: which series do you choose?

Solplanet ASW H-T2

The H‑T2 range runs from 5 to 12 kW and features two independent MPPT trackers. It combines solar production, a compatible high-voltage battery, grid connection and EPS emergency power in one IP66 housing.

Solplanet ASW H-T3

The H‑T3 range of 8, 10 and 12 kW offers three independent MPPT trackers. This provides extra flexibility with different roof orientations or PV strings. This series also supports high-voltage batteries, EPS and Solplanet monitoring.

What does the Synergrid entry mean?

Synergrid manages the Belgian C10/26 list of approved production units. An inverter that operates in parallel with the Belgian distribution network must appear in that list with the correct product reference before the connection procedure. For the above H‑T2 and H‑T3 models there is a separate entry for connection to a delta 3×230 V network.

The list mentions firmware for these versions V1.0 and the Eastron SDM630-Modbus. For each installation, check the exact device reference, firmware, Belgian network code, meter configuration, protections and the current requirements of the competent distribution network operator.

Technical advice for your 3×230 V project?

Solar-West helps installers choose the inverter, battery, energy meter and communication components. Log in for your personal B2B prices or request an installer account.

Log in for B2B pricingRequest a B2B account

Frequently asked questions about Solplanet on 3×230 V

Can I fully use the rated power on the nameplate at 3×230 V?

No. For the delta connection, Synergrid states adjusted maximum powers: 2.9 kVA, 3.5 kVA, 4.6 kVA, 5.8 kVA or 6.9 kVA, depending on the model. Dimension the installation based on the homologated 3×230 V listing.

Are both the H-T2 and H-T3 suitable for a battery?

Yes. They are three-phase hybrid inverters for a compatible high-voltage battery. Always check Solplanet's current compatibility list for the chosen battery and firmware.

Does the 3×230 V entry automatically apply to every variant?

No. The exact model reference is decisive. Versions with a different suffix or functions, such as certain DG variants with generator input, must be checked separately in the current Synergrid list.

Where do I check the current homologation?

Always consult the most recent Synergrid C10/26 list. That list is regularly updated.

Resources and documentation

Technical data and homologations may change. Always check the current official documentation and network requirements before ordering and commissioning.